ROOTALUM Beam Check Analysis — preliminary EC9 aluminium beam check (bending, shear and deflection)

Beam Check Analysis

Preliminary EC9 beam check — bending, shear and deflection, with a clear capacity-versus-span result and transparent verification status. From £75 per beam.

Working out whether an aluminium beam is strong enough shouldn't take an afternoon of hand calculations. Beam Check is ROOTALUM's second analysis service — a preliminary EC9 structural check of a single aluminium beam under a uniform load. You send the section and the loads; you get back a clear structured report showing whether the beam passes the selected checks — and by how much.

It is a real preliminary capacity check, not just a single number. Beam Check evaluates bending (MRd), shear (VRd) and deflection against your selected limit, and considers section classification, local buckling, lateral-torsional stability and declared weld / HAZ conditions where applicable. Every result carries a visible basis — Verified, Declared, Auto-estimated or Preliminary — so you know exactly what has been calculated, assumed or left outside the current scope.

See the whole capacity, at a glance

Each check is issued as a clear graphical report. The capacity overview shows how far the beam can go: a capacity-versus-span curve, and a summary table giving the governing limit — bending, shear or deflection — at every span.

ROOTALUM Beam Check — aluminium beam capacity versus span curve (EC9)

Capacity vs span — how much uniform load the beam safely carries at every span, before bending, shear or deflection governs.

ROOTALUM Beam Check — utilization bars showing bending, shear and deflection PASS

The summary table — net load and the governing limit at every span, in one readable view.

Your project, checked

Give us your exact span and load, and Beam Check confirms it: utilization bars and a clear PASS / limit status, with demand against capacity for bending, shear and deflection, and an overall assessment.

ROOTALUM Beam Check — capacity summary table of governing limit per span

Utilization at your span and load — demand against capacity, shown against the 100% limit.

ROOTALUM Beam Check — project check results, demand vs capacity, overall PASS

The verdict — demand versus capacity for bending, shear and deflection, with an overall PASS.

How it works

- Send a closed beam section (DXF) or its properties, plus span, support and loads.

- We run the EC9 engine and an engineer reviews the governing wall, class, stability and shear.

- You receive your Beam Check report — usually within 1–2 working days.


From £75 per beam check.

Note: Beam Check is a preliminary engineering assistance service. Final construction approval should always be reviewed against the current project requirements, applicable standards and responsible engineer approval where required.

Package files

English (PDF)

Arabic (PDF)

Looking Ahead

Strong structures start with checked beams. By reviewing each aluminium beam against EC9 principles — bending, shear, deflection and stability — ROOTALUM gives designers, fabricators and factories a clear preliminary result they can use for early decisions: traceable, readable and structured. Checked, not assumed. Calculated, not guessed. A dependable step in a complete aluminium engineering service.


📌 Discover more [ROOTALUM](https://alum.roothubs.com/) systems, product developments, and engineering solutions in our [Products & Features] section.

1
168
ROOTTOOLS ENG

ROOTTOOLS ENG

1721055047.png
ROOTHUBS
5 months ago
Aluminium Profile Engineering

Aluminium Profile Engineering

1753537053.png
RootAlum
1 month ago
R-T-W-70 Lite

R-T-W-70 Lite

1753537053.png
RootAlum
1 year ago
RootAlum – Your Engineering Partner

RootAlum – Your Engineering Partner

1753537053.png
RootAlum
1 year ago
RootAlum’s Multi-Layer Advantage

RootAlum’s Multi-Layer Advantage

1753537053.png
RootAlum
1 year ago